14
Ducane Ignition Lockout

Code 14, ignition lockout due to failed ignition attempts, requires manual reset

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective hot surface ignitor, Loose ignitor harness on Ducane board, Gas valve not opening, Flame sensor not proving flame

How to Fix / Troubleshooting

Safety first: Turn off power and gas before servicing ignition components.

  • Step 1 – Inspect and test ignitor: Remove the ignitor and visually inspect for cracks. Measure resistance with a multimeter; an open circuit indicates failure. Replace with the correct Ducane-rated ignitor.
  • Step 2 – Check harness connections: Ensure the ignitor plug is fully seated on the board and not heat-damaged.
  • Step 3 – Clean flame sensor: As described earlier, clean the flame sensor rod to ensure reliable flame detection.
  • Step 4 – Reset lockout: Restore power and gas, then cycle thermostat to clear lockout. If code 14 returns, professional diagnosis of gas valve and board is required.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Hot Surface Ignitor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements