31
Ducane Pressure Switch Fault During Run

Code 31, pressure switch did not close or reopened during operation

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Marginal inducer performance, Partial vent blockage on Ducane vent system, Water in pressure switch tubing, Faulty pressure switch contacts

How to Fix / Troubleshooting

Safety first: Turn off power and gas before working on the venting or pressure switch.

  • Step 1 – Check vent and intake: Inspect for obstructions, sagging vent pipes holding water, or disconnected joints.
  • Step 2 – Clear condensate: Clean the condensate trap and drain line. Ensure proper slope on horizontal vent runs to prevent water pooling.
  • Step 3 – Inspect tubing and ports: Remove and clear tubing, clean inducer port, and ensure tight connections.
  • Step 4 – Professional testing: If code 31 persists, a technician should measure draft and pressure switch operation under load.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Inducer Draft Motor Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements