43
Ducane Two-Stage Pressure Switch Fault

Code 43, low stage or high stage pressure switch fault on two-stage Ducane furnace

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect pressure switch for application, Vent length exceeding Ducane specifications, Weak inducer on high stage, Blocked vent or intake

How to Fix / Troubleshooting

Safety first: Turn off power and gas before working on venting or pressure switches.

  • Step 1 – Verify venting: Measure total vent length and number of elbows. Compare to Ducane installation manual limits. Shorten or correct venting if out of spec.
  • Step 2 – Inspect both pressure switches: Ensure tubing is correctly connected to low and high stage switches and not crossed.
  • Step 3 – Clear obstructions: Check terminations for blockages and clear as needed.
  • Step 4 – Professional evaluation: A technician should verify correct switch ratings and inducer performance.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Two-Stage Pressure Switch Set
Check Price on Amazon