E0
Ducane
Control Board Communication Fault
Control board shows E0, furnace will not start any heating cycle
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose low-voltage wiring to control board, Failed Ducane integrated furnace control (IFC) board, Incorrect line voltage polarity, Blown low-voltage fuse on control board
How to Fix / Troubleshooting
Safety first: Turn OFF power to the furnace at the service switch and breaker. Verify power is off with a non-contact voltage tester before touching any wiring.
- Step 1 – Inspect low-voltage wiring: Remove the blower door to access the Ducane IFC board. Check the R, C, W, Y, and G thermostat wires for loose connections, corrosion, or broken conductors. Tighten any loose terminal screws.
- Step 2 – Check the 3–5A blade or automotive-style fuse on the board: If the fuse is blown, inspect for shorts in thermostat wiring (especially where it passes through sheet metal). Replace the fuse with the same rating only after correcting any short.
- Step 3 – Confirm line voltage polarity and ground: Verify hot and neutral are correctly landed on the L1 and neutral terminals and that the ground wire is secure to the furnace chassis.
- Step 4 – Power cycle: Restore power and see if E0 clears. If the code returns immediately and wiring and fuse are good, the IFC board may be defective.
- Step 5 – When to call a pro: If you suspect a failed control board or incorrect supply wiring, contact a qualified HVAC technician. Board replacement and line-voltage diagnostics should be done by a professional.