E8
Ducane Pressure Switch Open Fault

E8 code, inducer runs but pressure switch does not prove, furnace shuts down

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked intake or exhaust vent, Cracked or disconnected pressure switch tubing, Weak inducer motor on Ducane furnace, Faulty pressure switch

How to Fix / Troubleshooting

Safety first: Turn off power and gas before working on venting or pressure switch components.

  • Step 1 – Inspect vent pipes: For PVC vented Ducane models, check both intake and exhaust terminations outside for snow, ice, leaves, or nests. Clear any obstructions. For metal flues, ensure the vent cap is clear.
  • Step 2 – Check condensate drain (condensing models): A clogged condensate trap or drain line can flood the inducer housing and prevent proper draft. Clean the trap and flush the drain line.
  • Step 3 – Examine tubing: Remove the rubber tubing from the pressure switch and inducer port. Blow through it to ensure it is clear. Replace if brittle or cracked. Clean the inducer port with a small drill bit or wire (do not enlarge the hole).
  • Step 4 – Reset and test: Reconnect tubing, restore power, and call for heat. If E8 persists, the pressure switch or inducer performance must be tested with a manometer by a technician.