E9
Ducane Pressure Switch Stuck Closed

E9 code, pressure switch remains closed when it should be open, furnace will not start

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Pressure switch contacts welded closed, Pressure switch tubing filled with water, Control board misreading switch status, Venting configuration causing constant draft

How to Fix / Troubleshooting

Safety first: Turn off power and gas before servicing the pressure switch or vent system.

  • Step 1 – Inspect tubing for water: Remove the tubing from the pressure switch and inducer. If water drips out, the condensate system is likely clogged. Clear the condensate trap and drain line.
  • Step 2 – Check switch at rest: With tubing removed and no call for heat, use a multimeter (ohms) across the pressure switch terminals. The switch should be open (infinite resistance). If it reads closed, the switch is stuck and must be replaced.
  • Step 3 – Inspect venting: Ensure there is no constant wind-driven draft or improper vent termination that could keep the switch pulled in.
  • Step 4 – Replace pressure switch if needed: Use a Ducane-approved replacement with the same rating (inches water column). A professional should verify correct operation after replacement.