Ducane
Low-Voltage Control Circuit Failure
Thermostat clicks but furnace does not respond, no inducer or blower
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown 24V transformer on Ducane furnace, Open low-voltage fuse, Broken R wire between transformer and thermostat, Shorted thermostat cable
How to Fix / Troubleshooting
Safety first: Turn off power before testing low-voltage circuits.
- Step 1 – Check board LED: If no LED or display is lit, the 24V control power may be lost.
- Step 2 – Inspect fuse: Replace blown low-voltage fuse on the board after checking for shorts in thermostat wiring.
- Step 3 – Test transformer (pro recommended): A technician should measure primary and secondary voltages on the transformer and replace if failed.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
24V Control Transformer
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements