Ferroli furnace locks out with A02, fan runs but burner shuts down shortly after ignition attempt.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Isolate power and gas before opening the combustion chamber. Only qualified personnel should work on sealed combustion components.
Steps:
- Visual inspection: Remove the front panel and check for loose earth (ground) wires on the burner, gas valve, and control board chassis. Tighten any loose screws.
- Clean flame sensor: Remove the ionisation electrode and gently clean the metal rod with fine abrasive pad. Avoid bending the rod. Reinstall ensuring correct gap and position in the flame.
- Check burner condition: Inspect for corrosion, soot, or partial blockage that could cause unstable flame. Clean with a soft brush and vacuum.
- Check condensate trap (if condensing model): A blocked Ferroli condensate trap can disturb combustion. Remove the trap, flush with water, and ensure the drain line is clear.
- Monitor operation: Restore power and gas, reset the unit, and observe ignition. If the flame lights but drops out, gas pressure or control board may be at fault.
Professional help: A licensed technician should measure gas inlet and burner pressure, verify correct combustion with an analyser, and replace the control board or gas valve if the flame signal remains unstable.
Repair Difficulty
Required Part
We may earn a commission from links on this page.