A06
Ferroli Ignition Lockout / Repeated Failed Ignitions

Display shows A06; ignition attempts may be noisy or irregular, with delayed flame establishment.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect electrode gap on Ferroli ignition electrode, Weak ignition transformer, Poor gas/air mixture due to blocked burner or venturi, Low gas inlet pressure to Ferroli gas valve

How to Fix / Troubleshooting

Safety: Isolate power and gas before accessing the burner compartment. Only qualified personnel should adjust combustion settings.

Steps:

  • Check electrode position: Compare the ignition electrode position and gap to the Ferroli service manual. If visibly misaligned or bent, it should be adjusted or replaced by a technician.
  • Clean burner and venturi: Remove loose dust and debris from the burner and air intake area with a soft brush and vacuum. Do not use compressed air inside the combustion chamber.
  • Check air inlet (for room-sealed models): Ensure the air intake section of the concentric flue is not blocked externally.
  • Reset and test: Restore power and gas, reset the unit, and observe ignition. If ignition remains weak or delayed, further electrical and gas pressure tests are required.

Professional help: A technician should test ignition transformer output, verify gas pressures, and replace the ignition assembly or gas valve if necessary.