A10
Ferroli
External Thermostat / Room Control Fault
Display shows A10; Ferroli furnace may not respond to thermostat or may behave erratically.
Advertisements
Possible Causes
Open or short circuit in room thermostat wiring, Incorrect connection of Ferroli remote control or OpenTherm device, Faulty external thermostat or programmer
How to Fix / Troubleshooting
Safety: Isolate power before working on control wiring.
Steps:
- Check thermostat settings: Ensure the room thermostat or Ferroli controller is calling for heat and not in OFF or holiday mode.
- Inspect wiring: At the furnace terminal strip, verify that thermostat wires are securely connected and not damaged. Tighten loose screws.
- Bypass test (qualified persons only): Temporarily link the room thermostat terminals at the furnace to simulate a call for heat. If the unit runs normally, the external thermostat or its wiring is faulty.
- Reset controls: Power-cycle the furnace and any Ferroli-branded controller to clear communication glitches.
Professional help: Complex control systems (e.g., OpenTherm, modulating controls) should be diagnosed by a technician familiar with Ferroli control protocols.