E5
Frigidaire Rollout Switch Open / Flame Rollout Detected

Furnace runs briefly then shuts off; E5 code on control board

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked heat exchanger, Blocked flue, Cracked heat exchanger causing abnormal flame, Tripped manual-reset rollout switch

How to Fix / Troubleshooting

Critical safety warning: A rollout condition can indicate serious combustion or heat exchanger problems and risk of fire or carbon monoxide. Do not repeatedly reset rollout switches without finding the cause.

  • 1. Power and gas off: Turn off the furnace power and close the gas shutoff valve.
  • 2. Visual inspection: Remove burner access panel. Look for signs of scorching, melted wiring, or soot around the burners and rollout switches.
  • 3. Check venting: Inspect the flue pipe for disconnections, crushing, or blockages. Do not operate the furnace with a blocked flue.
  • 4. Rollout switch reset: Locate the rollout switches near the burner area. Some have a small red reset button. If tripped, press firmly until it clicks. Only reset once after verifying there is no visible blockage or damage.
  • 5. Do not bypass: Never jumper or bypass a rollout switch. This is a critical safety device.
  • 6. Professional inspection required: If the rollout switch trips again, or if you see flame coming out of the burner area, shut the system down and call a qualified HVAC technician immediately to inspect the heat exchanger, burners, and venting.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Flame Rollout Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements