Possible Causes

Improper flame sensor grounding, Incorrect burner alignment, Contaminated flame sensor, Faulty control board

How to Fix / Troubleshooting

Safety: Turn off power and gas before servicing.

  • 1. Clean flame sensor: Remove and polish the sensor rod with fine steel wool. Reinstall ensuring the sensor is fully in the flame.
  • 2. Tighten grounds: Tighten screws on the burner rack, gas valve, and control board ground lug. Clean off rust or paint that may interfere with grounding.
  • 3. Inspect burners: Verify burners are properly seated and flames are stable and blue.
  • 4. Professional testing: A technician can measure flame rectification current and replace the control board if the flame signal is correct but F3 persists.