F3
Frigidaire
Flame Sense Out of Range / Flame Current Error
Furnace flashes F3; burners may light then shut off quickly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Improper flame sensor grounding, Incorrect burner alignment, Contaminated flame sensor, Faulty control board
How to Fix / Troubleshooting
Safety: Turn off power and gas before servicing.
- 1. Clean flame sensor: Remove and polish the sensor rod with fine steel wool. Reinstall ensuring the sensor is fully in the flame.
- 2. Tighten grounds: Tighten screws on the burner rack, gas valve, and control board ground lug. Clean off rust or paint that may interfere with grounding.
- 3. Inspect burners: Verify burners are properly seated and flames are stable and blue.
- 4. Professional testing: A technician can measure flame rectification current and replace the control board if the flame signal is correct but F3 persists.
Advertisements
Repair Difficulty
Hard
4/5