Frigidaire
Continuous Blower Operation
Furnace blower runs continuously even when thermostat is not calling for heat
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Thermostat fan set to ON, Stuck blower relay on control board, Open limit switch, Miswired thermostat
How to Fix / Troubleshooting
Safety: Turn off power before accessing the control board.
- 1. Thermostat setting: Check that the fan setting is on AUTO, not ON.
- 2. Reset power: Turn furnace power off for 5 minutes, then restore. If the blower starts immediately with no call for heat, suspect a stuck relay or open limit.
- 3. Limit switch check: An open high limit can cause the board to run the fan continuously. Replace a faulty limit switch after confirming airflow is adequate.
- 4. Board relay: If the limit is closed and thermostat is not calling, the blower relay on the control board may be stuck closed and the board will need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Integrated Furnace Control Board