9 FLASHES
Gibson
Reversed Line Polarity or Grounding Issue
Status LED flashes nine times, blower may run continuously without heat
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Hot and neutral wires reversed at furnace junction box, Shared neutral or improper grounding, Miswired service disconnect, Faulty house wiring affecting Gibson control board sensing
How to Fix / Troubleshooting
Safety first: Turn off power at the main breaker panel before inspecting wiring. If you are not comfortable working with electrical wiring, contact a licensed electrician.
Steps to check:
- Inspect furnace power connection: Remove the electrical junction box cover on the furnace. Verify that the black (hot) wire is connected to the furnace hot lead and the white (neutral) to the neutral lead, with ground connected to the green screw.
- Check service outlet (if present): Use a plug-in outlet tester to verify correct polarity and grounding at any service receptacle near the furnace.
- Correct any miswiring: If hot and neutral are reversed, correct the connections and secure all wire nuts.
- Restore power and test: Turn the breaker back on and call for heat. If the code remains, the control board may have been damaged by improper wiring and should be checked by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Line Voltage Wiring Harness
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements