9 FLASHES
Gibson Reversed Line Polarity or Grounding Issue

Status LED flashes nine times, blower may run continuously without heat

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Hot and neutral wires reversed at furnace junction box, Shared neutral or improper grounding, Miswired service disconnect, Faulty house wiring affecting Gibson control board sensing

How to Fix / Troubleshooting

Safety first: Turn off power at the main breaker panel before inspecting wiring. If you are not comfortable working with electrical wiring, contact a licensed electrician.

Steps to check:

  • Inspect furnace power connection: Remove the electrical junction box cover on the furnace. Verify that the black (hot) wire is connected to the furnace hot lead and the white (neutral) to the neutral lead, with ground connected to the green screw.
  • Check service outlet (if present): Use a plug-in outlet tester to verify correct polarity and grounding at any service receptacle near the furnace.
  • Correct any miswiring: If hot and neutral are reversed, correct the connections and secure all wire nuts.
  • Restore power and test: Turn the breaker back on and call for heat. If the code remains, the control board may have been damaged by improper wiring and should be checked by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Line Voltage Wiring Harness
Check Price on Amazon