F12
Glow-worm Gas valve control fault

F12 displayed, furnace locks out intermittently, often during high demand

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective gas valve coil, Loose gas valve connector on Glow-worm PCB, Faulty gas valve modulation control, PCB output fault to gas valve

How to Fix / Troubleshooting

Critical safety: All gas valve testing and replacement must be carried out by a Gas Safe registered engineer. Do not attempt DIY repairs on gas components.

Technician procedure:

  • Check the electrical connector at the gas valve for secure fit and signs of overheating.
  • Measure coil resistance and compare with Glow-worm specifications.
  • Verify that the PCB is sending the correct voltage to the gas valve during ignition and modulation.
  • Check gas inlet pressure and ensure the supply is stable.
  • Replace the gas valve assembly if it fails electrical or mechanical tests, and recommission the appliance with full combustion analysis.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve Assembly
Check Price on Amazon