F20
Glow-worm Primary circuit flow restriction / overheat

F20 displayed, furnace overheats and locks out frequently

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked plate heat exchanger (on combi units), Sludged primary heat exchanger, Closed isolation valves under Glow-worm furnace, Faulty or stuck motorised valve

How to Fix / Troubleshooting

Safety: Allow the system to cool fully. Surfaces and water may be very hot.

User checks:

  • Ensure all radiator valves are open.
  • Check that isolation valves under the appliance are fully open (if accessible and clearly marked).

Technician actions:

  • Inspect and clean or replace the plate heat exchanger if blocked with scale or sludge.
  • Check the primary heat exchanger for flow and consider powerflushing the system.
  • Verify operation of any external motorised valves controlling heating circuits.
  • Ensure the pump is correctly sized and functioning.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Plate Heat Exchanger
Check Price on Amazon

We may earn a commission from links on this page.