F7
Glow-worm
Return temperature sensor fault
F7 error, furnace may overheat quickly or show incorrect temperature readings
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective return NTC sensor, Wiring fault between return sensor and Glow-worm PCB, Sensor not in good contact with return pipe, Moisture ingress in sensor connector
How to Fix / Troubleshooting
Safety: Turn off power and allow the system to cool.
Technician procedure:
- Identify the return NTC sensor on the return pipe entering the heat exchanger.
- Check that the sensor is firmly clipped to the pipe with thermal paste or good contact.
- Test resistance of the NTC and compare with manufacturer’s chart.
- Inspect wiring and connectors for damage or corrosion; repair or replace as needed.
- Fit a new Glow-worm compatible return NTC sensor if faulty.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Return Temperature NTC Sensor
Check Price on Amazon
We may earn a commission from links on this page.