Frozen or restricted condensate / air in heat exchanger
Furnace locks out more often during very cold weather, with gurgling sounds
Advertisements
Possible Causes
Frozen external condensate pipe, Air trapped in Glow-worm primary heat exchanger, Low system pressure, Inadequate pipe insulation
How to Fix / Troubleshooting
Safety: Take care when working outside in icy conditions.
User steps:
- Check and thaw the external condensate pipe if frozen using warm water.
- Top up system pressure to the recommended level if low.
- Bleed radiators to remove air.
Technician steps:
- Bleed air from the heat exchanger and high points in the system.
- Insulate external condensate pipework and increase diameter if necessary to Glow-worm recommendations.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condensate Pipework
Check Price on Amazon