Glow-worm
Control stuck on / thermostat failure
Furnace runs continuously and overheats the house, even when thermostat is turned down
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck relay on Glow-worm PCB, Room thermostat contacts welded closed, Faulty external programmer, Incorrect wiring bypassing controls
How to Fix / Troubleshooting
Safety: Overheating can stress the system. Turn down the boiler flow temperature as a temporary measure.
User steps:
- Turn the room thermostat fully down and set programmer to OFF; if the furnace continues to run, switch off at the isolator.
Technician steps:
- Test room thermostat and programmer outputs; replace if stuck on.
- Check wiring for any permanent links across call-for-heat terminals.
- Inspect PCB relays controlling the burner and pump; replace PCB if relays are welded closed.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Room Thermostat / Main PCB