Possible Causes
Blocked burner injectors, Incorrect gas/air ratio on Glow-worm burner, Flue blockage, Low gas pressure
How to Fix / Troubleshooting
Safety: Poor combustion can produce carbon monoxide. Do not continue to reset the appliance.
User steps:
- Check that the flue terminal is not obstructed.
- Contact a Gas Safe engineer for combustion checks.
Technician steps:
- Inspect and clean the burner and injectors.
- Perform a full combustion analysis and adjust gas valve and air settings as per Glow-worm instructions.
- Check gas inlet pressure and flue integrity.