Glow-worm
No power to appliance
Furnace will not start, no lights or display, completely dead
Advertisements
Possible Causes
Blown 3A/5A fuse in fused spur, Tripped circuit breaker, Faulty Glow-worm on/off switch, Loose mains wiring connection
How to Fix / Troubleshooting
Safety: Do not remove the appliance cover unless you are competent. Isolate power before touching any wiring.
User steps:
- Check that the wall isolator switch is turned on.
- Inspect the consumer unit for a tripped breaker and reset if appropriate.
- Check and replace the fuse in the fused spur with the correct rating if blown.
- Ensure any external timeclock or programmer is powered and set to ON or a timed period.
Technician steps:
- Verify mains voltage at the appliance terminals.
- Test the appliance on/off switch and replace if faulty.
- Inspect internal fuses on the Glow-worm PCB and replace only with identical types if blown, after finding the root cause.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Fused Spur / Main Switch
Check Price on Amazon