7 FLASHES
Goodman
Flame Loss During Run
Furnace shuts down; LED shows 7 flashes; blower may continue to run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty flame sensor, Low gas pressure, Intermittent gas valve, Poor burner grounding or dirty burners
How to Fix / Troubleshooting
Safety: Turn off power and gas before removing burner assembly or gas components.
Steps:
- Clean flame sensor: Remove and gently clean the flame sensor rod with fine steel wool. Reinstall and ensure it is fully in the burner flame.
- Clean burners: Remove burner assembly if accessible. Use a soft brush or compressed air to remove rust and debris from burner ports. Ensure crossover ports are clear for proper flame carryover.
- Check gas supply: Confirm other gas appliances operate normally. If multiple appliances show issues, contact the gas utility.
- Observe flame: With panels in place and power restored, watch through the sight glass. Flames should be stable, blue, and not lifting or blowing off the burners. Yellow, unstable, or lifting flames indicate gas or combustion issues requiring professional adjustment.
If flame continues to drop out during operation, a technician should check manifold gas pressure, gas valve operation, and combustion air supply.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Burner Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements