2 FLASH
Heil Pressure Switch Stuck Closed

Heil furnace LED flashes 2 times; inducer runs but burners do not light, or furnace shuts down shortly after starting.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Pressure switch contacts welded closed, Blocked pressure switch tubing, Faulty control board sensing circuit, Incorrect pressure switch for application

How to Fix / Troubleshooting

Safety: Turn off power before opening the blower or burner compartment. Do not bypass the pressure switch for operation; it is a critical safety device.

Steps to check:

  • Locate the pressure switch: Round or oval device with two wires and one or two rubber tubes, mounted near the inducer assembly.
  • Inspect tubing: Remove the rubber hose(s) from the pressure switch and inducer port. Check for water, debris, or cracks. Blow gently through the tubing to clear any blockage. Reconnect firmly.
  • Check switch operation: With power off, disconnect the wires and use a multimeter on continuity. At rest (no inducer running), the switch should be open. If it reads closed, the switch is stuck and should be replaced.
  • Check venting: Make sure the PVC exhaust and intake pipes (if 90%+ Heil furnace) are not blocked by ice, leaves, or nests. Clear any obstructions.
  • Reset and test: Restore power, call for heat, and observe if the error clears.

When to call a pro: If the pressure switch tests closed at rest or does not change state with inducer operation, or if you suspect incorrect vent sizing, have a professional evaluate and replace the switch or correct venting.