Heil furnace LED shows code 31; inducer may run but pressure switch does not close, or furnace shuts down on pressure fault.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Turn off power and gas before working on venting or condensate lines.
Steps to check:
- Inspect vent and intake: Check outside terminations for obstructions (ice, snow, nests). Clear any blockage and ensure proper clearances per Heil installation manual.
- Check condensate drain: For condensing Heil furnaces, inspect the condensate trap and hoses for clogs or kinks. Flush the trap with warm water and reassemble.
- Examine inducer housing: Look for water accumulation in the inducer assembly. A blocked drain can cause water to back up and affect pressure.
- Test pressure switch tubing: Remove and clear tubing, then reattach securely.
When to call a pro: If the pressure switch still does not close with clear venting and drains, a technician should measure draft pressure, verify correct switch rating, and replace the inducer or pressure switch as needed.