Heil Flame Sensing / Proving Failure

Furnace burners light but go out after a few seconds; this repeats several times.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty flame sensor, Poor ground connection, Flame not reaching sensor due to dirty burners, Low gas pressure

How to Fix / Troubleshooting

Safety: Turn off power and gas before cleaning components.

Steps to check:

  • Clean flame sensor: Remove and polish the sensor rod with fine steel wool. Reinstall securely.
  • Check burner cleanliness: Inspect burners for rust and debris; clean with a soft brush if accessible.
  • Verify ground: Ensure the furnace ground wire is tight and there is no corrosion at the ground lug.

When to call a pro: If the problem persists, a technician should measure flame signal, adjust gas pressure, and thoroughly clean or replace burners.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Flame Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements