Condensate drainage restriction
Condensate drain gurgles loudly and occasionally backs up
Advertisements
Possible Causes
Partially blocked condensate trap, Incorrect fall on condensate pipe, Air lock in condensate line, Undersized condensate pipe
How to Fix / Troubleshooting
Safety: Condensate is mildly acidic; wear gloves.
- Clean trap: Remove and flush the condensate trap to clear sludge.
- Check slope: Ensure the condensate pipe runs downhill continuously with no upward loops.
- Vent line: If allowed by local codes, provide an air break or vent to prevent siphoning.
- Monitor: After cleaning, run the furnace and confirm steady condensate flow without backing up.