A02
Hoval Flame supervision failure

Burner starts but flame is unstable and goes out, followed by lockout

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Contaminated ionisation electrode, Poor burner earth connection on Hoval burner plate, Incorrect gas/air ratio at Hoval premix burner, Faulty flame monitoring circuit on Hoval control board

How to Fix / Troubleshooting

Safety: Isolate power and close the gas valve before working on the burner. Wait for the furnace to cool.

  • Clean ionisation electrode: Remove and clean the electrode tip with fine abrasive pad to remove oxidation. Ensure the electrode is positioned correctly in the flame envelope as specified by Hoval.
  • Check grounding: Verify that the burner plate and control panel earth wires are securely fastened to clean metal surfaces. Tighten loose screws and remove corrosion.
  • Inspect burner head: Remove the premix burner head and check for blocked ports or corrosion. Clean with a soft brush and vacuum. Do not use sharp tools that may damage the burner surface.
  • Check combustion air path: Ensure the combustion air intake and fan housing are free of dust and debris that could disturb the flame.
  • Test operation: Restore gas and power, reset the lockout, and observe the flame through the inspection window. If the flame remains unstable or the fault recurs, a technician must check gas valve settings and the control board.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Hoval Burner Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements