A14
Hoval Combustion fan failure

Furnace indicates fan fault, combustion fan does not run or runs erratically

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized fan motor on Hoval burner, Faulty fan speed control module, Loose fan wiring, Obstruction in fan wheel

How to Fix / Troubleshooting

Safety: Isolate power. Moving fan blades can cause injury.

  • Access fan: Remove the burner cover to access the combustion fan assembly.
  • Check for obstructions: Inspect the fan wheel for debris, insulation, or broken pieces. Remove any foreign objects.
  • Spin test: Gently rotate the fan wheel by hand. It should turn freely without grinding. If stiff or seized, the motor likely needs replacement.
  • Inspect wiring: Check the fan motor plug and any speed control module connections for looseness or burn marks.
  • Reset and test: Restore power and call for heat. If the fan still fails to start or the error persists, a technician should test the motor and control module.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Combustion Fan Motor
Check Price on Amazon