F8
Ideal Control Board / Internal Electronics Fault

Ideal furnace shows F8, blower runs but no heat, or intermittent heating with control board error

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed Ideal main control PCB, damaged relay contacts, surge damage, internal sensor circuit failure

How to Fix / Troubleshooting

Safety: Isolate power before touching the control board. Electronic components are static-sensitive.

Steps:

  • Power cycle: Turn off the furnace at the breaker for 5 minutes, then restore power and call for heat. Observe if the error clears temporarily.
  • Inspect the PCB: Remove the blower door and visually inspect the Ideal control board for burnt areas, swollen capacitors, or loose connectors. Reseat all multi-pin plugs firmly.
  • Check for external causes: Verify correct line voltage at the furnace and that neutral and earth connections are tight. Surges or incorrect wiring can damage the board.
  • If F8 persists: The control board is likely defective. Replacement and configuration (if required) should be performed by a qualified technician following Ideal’s service instructions.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements