06
Immergas
Flow Temperature Sensor (NTC) Fault
Display shows 06, furnace does not start, may occur immediately on power-up
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open-circuit or shorted flow NTC sensor, Damaged NTC wiring harness, Faulty main control PCB input
How to Fix / Troubleshooting
Safety: Turn off power before accessing the electronic board or sensors.
Steps:
- 1. Power cycle: Turn the furnace off at the main switch for 30 seconds, then back on. If 06 reappears, proceed.
- 2. Locate flow NTC: On Immergas furnaces, the flow NTC is usually clipped or screwed into the flow pipe leaving the primary heat exchanger. Refer to your model diagram.
- 3. Visual inspection: Check the sensor and its connector for corrosion, broken wires, or signs of water leakage. Reseat the connector firmly.
- 4. Resistance check (technician): A technician can measure the NTC resistance at room temperature and compare it to Immergas specifications. If out of range or open/shorted, replace the flow NTC sensor.
- 5. PCB check: If the sensor and wiring are good, the main PCB analog input may be defective and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Flow NTC Temperature Sensor
Check Price on Amazon