40
Immergas
Air Pressure Switch Stuck or Not Changing State
Furnace shows 40, no operation, may be related to fan proving or air pressure
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Pressure switch stuck closed or open, Blocked pressure tubing, Incorrect flue configuration
How to Fix / Troubleshooting
Safety: Turn off power before working on internal components.
Steps:
- 1. Inspect pressure switch: Check that the switch is mounted correctly and that tubes are connected to the correct ports.
- 2. Clean tubes: Remove and blow through tubes to clear any blockage. Ensure no water is present.
- 3. Technician test: Use a multimeter to verify that the switch changes state when the fan runs. Replace the switch if it does not operate correctly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Air Pressure Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements