Immergas No Power / Dead Appliance

Furnace does not start at all, display is blank or dead

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown fuse on PCB, No mains supply or tripped breaker, Faulty main switch, Defective PCB power supply section

How to Fix / Troubleshooting

Safety: Electrical work must be done with power isolated and by competent persons.

Steps:

  • 1. Check mains supply: Verify that the circuit breaker or fused spur feeding the boiler is on and the fuse is intact.
  • 2. Test outlet or spur: Plug in another device or use a tester to confirm power is present.
  • 3. Inspect boiler fuse: Many Immergas boards have an internal fuse. A technician can check and replace it with the correct rating if blown, but must also identify the cause.
  • 4. PCB replacement: If power is present but the display remains dead, the PCB power supply is likely faulty and the board must be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.