Immergas
Short Cycling / Oversized Boiler or Poor Control Strategy
Furnace frequently cycles on and off, radiators get hot quickly then cool, short cycling
Advertisements
Possible Causes
Boiler power too high for system, Flow temperature set too high, Inadequate water volume or bypass, Faulty or poorly placed room thermostat
How to Fix / Troubleshooting
Safety: Adjust only user-accessible settings unless you are a trained technician.
Steps:
- 1. Lower flow temperature: Reduce the heating flow temperature on the Immergas panel to lengthen burner run times.
- 2. Check thermostat location: Ensure the thermostat is not in a small or very warm room; relocate if necessary.
- 3. Open more radiators: Avoid closing too many radiators, which reduces system volume and causes rapid temperature rise.
- 4. Technician solutions: Adjust minimum power, install a buffer tank or hydraulic separator if needed, and verify correct bypass valve setting.
Advertisements
Repair Difficulty
Easy
2/5