Immergas Unstable Flame / Early Shutdown

Furnace starts but shuts down after a few seconds without showing a specific error code

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect gas pressure, Partially blocked burner, Faulty ionization signal, Fan speed not matching combustion requirements

How to Fix / Troubleshooting

Safety: Combustion adjustments and burner cleaning should be done by a gas-qualified technician.

Steps:

  • 1. Observe flame (technician): Check flame shape and stability through the inspection window.
  • 2. Clean burner: Remove and clean the burner assembly to remove dust or debris.
  • 3. Check gas pressures and combustion: Adjust according to Immergas specifications.
  • 4. Verify ionization electrode and wiring: Ensure a stable flame signal is present.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Burner Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements