Possible Causes

Cracked condensate trap, Blocked condensate outlet causing overflow, Damaged flue seals or joints

How to Fix / Troubleshooting

Safety: Condensate is mildly acidic; wear gloves and protect surrounding surfaces.

Steps:

  • 1. Inspect condensate trap and hoses: Look for cracks or loose connections. Replace damaged hoses or trap.
  • 2. Clear blockage: Disconnect the condensate pipe at a convenient point and flush with water to remove sludge.
  • 3. Check flue joints: Ensure internal flue connections are properly seated and sealed. Any damaged seals must be replaced by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condensate Trap and Seals
Check Price on Amazon