Intergas
Frozen Condensate Pipe
Boiler frequently locks out during very cold weather, condensate pipe outside is icy
Advertisements
Possible Causes
Condensate pipe run externally without insulation, Insufficient pipe diameter, Long horizontal runs exposed to cold
How to Fix / Troubleshooting
Safety first: Turn off the boiler before working on the condensate pipe. Take care on icy surfaces.
Steps:
- Thaw pipe: Pour warm (not boiling) water along the length of the external condensate pipe to melt ice. Do not use open flames.
- Reset boiler: Once thawed, reset the Intergas boiler and check for normal operation.
- Prevent recurrence: Insulate the external condensate pipe and, if possible, increase its diameter and reduce external runs as per Intergas and local guidelines.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condensate pipework
Check Price on Amazon