17
Intergas Communication Fault with Room Thermostat / OpenTherm

Code 17 displayed, boiler does not respond to external controls correctly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open circuit in OpenTherm or on/off control wiring, Incompatible thermostat, Faulty Intergas communication module, Reversed polarity on control bus

How to Fix / Troubleshooting

Safety first: Turn off power before working on low-voltage control wiring.

Steps:

  • Check thermostat type: Ensure the connected room thermostat or controller is compatible with the Intergas boiler (e.g. OpenTherm vs simple on/off).
  • Inspect wiring: Verify that the control wires are connected to the correct terminals on both the thermostat and the boiler. Look for loose or damaged cables.
  • Test continuity: With power off, test continuity of the control circuit. Repair any breaks.
  • Bypass test (technician): Temporarily link the boiler's room thermostat terminals to simulate a call for heat. If the boiler responds, the external control or wiring is at fault.

If communication still fails with known-good wiring and controls, the Intergas communication module or PCB may need replacement.