9
Intergas Return Temperature Sensor / NTC Fault

Code 9 appears, boiler stops and may show abnormal temperature readings

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open circuit return NTC, Shorted return NTC, Loose connector on return sensor, Faulty PCB return sensor input

How to Fix / Troubleshooting

Safety first: Turn off power and allow the system to cool.

Steps:

  • Locate return NTC: Find the NTC sensor on the heating return pipe entering the Intergas boiler.
  • Check mounting: Ensure the sensor is properly clipped and has good thermal contact with the pipe.
  • Inspect wiring: Look for damaged cable or loose connectors at both the sensor and PCB ends.
  • Measure resistance (technician): Disconnect and test the NTC resistance at ambient temperature. Replace if readings are out of spec or intermittent when the cable is flexed.

If a new return NTC does not resolve code 9, the main PCB may require replacement by a qualified technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Return NTC sensor
Check Price on Amazon

We may earn a commission from links on this page.