Poor DHW Performance
Radiators get hot but domestic hot water temperature fluctuates or is too cold
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Scaled plate heat exchanger, Partially blocked DHW flow sensor, Incorrect DHW temperature setting, Faulty DHW NTC sensor
How to Fix / Troubleshooting
Safety first: Isolate power and close cold water inlet before removing DHW components.
Steps:
- Check DHW setpoint: On the Intergas control panel, verify that the DHW temperature is set appropriately (e.g. 50–60°C).
- Clean inlet filter: Remove and clean the cold water inlet filter to ensure adequate flow.
- Descale plate heat exchanger (technician): Isolate and remove the DHW plate heat exchanger. Flush with a suitable descaling solution to remove limescale.
- Inspect DHW NTC: Check the DHW temperature sensor for secure mounting and replace if readings are erratic.