Intergas Poor DHW Performance

Radiators get hot but domestic hot water temperature fluctuates or is too cold

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Scaled plate heat exchanger, Partially blocked DHW flow sensor, Incorrect DHW temperature setting, Faulty DHW NTC sensor

How to Fix / Troubleshooting

Safety first: Isolate power and close cold water inlet before removing DHW components.

Steps:

  • Check DHW setpoint: On the Intergas control panel, verify that the DHW temperature is set appropriately (e.g. 50–60°C).
  • Clean inlet filter: Remove and clean the cold water inlet filter to ensure adequate flow.
  • Descale plate heat exchanger (technician): Isolate and remove the DHW plate heat exchanger. Flush with a suitable descaling solution to remove limescale.
  • Inspect DHW NTC: Check the DHW temperature sensor for secure mounting and replace if readings are erratic.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

DHW plate heat exchanger
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements