C6
Junkers Fan Speed Too Low / Fan Feedback Error

Error C6, furnace attempts to start but shuts down with fan-related fault

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially blocked flue or condensate trap, Failing fan motor bearings, Defective fan speed sensor, Incorrect fan wiring or connector issue

How to Fix / Troubleshooting

Safety first: Disconnect power and gas. Risk of flue gas spillage if airflow is inadequate.

  • 1. Inspect condensate system: Check the condensate trap and drain hose for blockage. A full or blocked trap can restrict flue gas flow. Clean the trap and ensure the drain is free-flowing.
  • 2. Check flue for restriction: Inspect the entire visible length of the flue for sagging, disconnections, or crushing. Ensure terminal is clear.
  • 3. Fan cleaning: Remove the fan as per Junkers service instructions. Clean the impeller blades thoroughly. Dust buildup can reduce airflow and speed.
  • 4. Mechanical check: Spin the fan shaft by hand. If there is resistance, noise, or wobble, replace the fan assembly.
  • 5. Electrical verification: Confirm that the fan receives the correct supply voltage and that the feedback/speed signal wire is intact. If the fan runs but the PCB does not detect correct speed, replace the fan or PCB as recommended by Junkers.
  • 6. Professional testing: Airflow and combustion checks should be performed by a qualified technician using proper instruments.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Combustion Fan Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements