Junkers Control Signal Not Received

Furnace display works but no response to room thermostat, heating does not start

Advertisements

Possible Causes

Faulty room thermostat, Broken thermostat cable, Incorrect wiring at Junkers control terminals, Misconfigured control mode

How to Fix / Troubleshooting

Safety first: Isolate power before working on control wiring.

  • 1. Check thermostat settings: Ensure the room thermostat is set above room temperature and in heating mode.
  • 2. Wiring inspection: Verify that thermostat wires are correctly connected to the designated Junkers terminals (e.g., TA, BUS) according to the wiring diagram.
  • 3. Bypass test: Temporarily bridge the thermostat contacts at the boiler. If the boiler starts, the thermostat or its wiring is faulty.
  • 4. Replace thermostat: Install a compatible Junkers or approved thermostat if the existing one is defective.
Advertisements

Repair Difficulty

Easy 2/5