Keeprite No Heat / Lukewarm Air

Cold air blows from vents when the furnace runs, or air is only slightly warm.

Advertisements

Possible Causes

Burners not lighting, Gas supply off, High limit tripping and shutting burners off, Thermostat fan set to ON

How to Fix / Troubleshooting

Steps:

  • Check thermostat: Ensure it is set to HEAT and fan is set to AUTO.
  • Observe furnace: Look through the sight glass to see if burners are lit during operation. If not, check for ignition-related error codes.
  • Verify gas valve: Confirm the manual gas shutoff is open.
  • Check filter: Replace a dirty filter that may be causing limit trips and shutting off burners.

If burners will not stay lit or never light, further diagnosis of ignition and gas components by a technician is required.