31 (Alt)
Keeprite
Loss of Draft During Operation
On some Keeprite models, code 31 indicates pressure switch open during run; furnace may shut off mid-cycle.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Intermittent vent blockage, Condensate backing up into inducer, Weak inducer motor, Loose pressure switch tubing during run
How to Fix / Troubleshooting
Safety: Turn off power and gas before opening the inducer or vent connections.
Steps:
- Check for intermittent vent blockage: Inspect vent terminations for flapping debris, insect screens, or snow that could intermittently block flow.
- Inspect condensate drain: Ensure the condensate trap and hoses are clear and that water is not backing up into the inducer housing. Clean and flush as needed.
- Secure tubing: Make sure the pressure switch tubing is firmly attached and not vibrating loose during operation.
- Monitor inducer current draw: A motor drawing high current or slowing during run may be failing and should be replaced.
Because loss of draft can lead to unsafe operation, have a professional verify combustion and venting after repairs.