Keeprite Flame Sensing Failure

Furnace burners light but shut off after a few seconds; this repeats several times before lockout.

Advertisements

Possible Causes

Dirty flame sensor, Poor burner ground, Flame not properly contacting sensor, Faulty control board flame circuit

How to Fix / Troubleshooting

Safety: Turn off power and gas before removing the flame sensor.

Steps:

  • Locate and remove flame sensor: It is a small metal rod in front of one burner with a single wire attached.
  • Clean sensor: Gently rub the rod with fine steel wool or emery cloth until shiny. Do not sand aggressively or bend the rod.
  • Reinstall and tighten: Reinstall the sensor, ensuring it is fully inserted into the flame path and the mounting screw is tight.
  • Check ground: Verify that the burner rack and control board ground wires are secure.

If the problem persists after cleaning, the control board or wiring may need professional diagnosis.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Flame Sensor
Check Price on Amazon

We may earn a commission from links on this page.