Keeprite Gas Valve Not Opening

Furnace runs inducer and ignitor but burners never light; you may smell a faint gas odor near the furnace.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Closed manual gas shutoff, Faulty gas valve coil, Broken gas valve wiring, Low gas supply pressure

How to Fix / Troubleshooting

Safety: If you smell strong gas in the area, evacuate and call the gas utility immediately. Do not operate electrical switches.

Steps (if only faint odor at furnace and no general leak):

  • Check manual gas valve: Ensure the handle on the gas cock near the furnace is parallel to the pipe (open position).
  • Inspect wiring: With power off, verify that the gas valve wires are firmly connected and not damaged.
  • Observe ignition sequence: Restore power and call for heat. Confirm that the ignitor glows and you hear a click from the gas valve. If there is no click and no flame, the valve or control board may be faulty.

Gas valve testing and replacement must be done by a licensed technician with proper leak testing equipment.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements