E12
Kelvinator
Pressure Switch Stuck Closed
Kelvinator furnace shows E12 and the inducer runs continuously without ignition
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Pressure switch contacts welded closed, Pressure tubing misrouted causing constant vacuum, Control board misreading pressure switch circuit
How to Fix / Troubleshooting
Safety first: Turn OFF power before disconnecting any pressure tubing or wiring.
- Inspect tubing routing: Verify the rubber tube from the inducer housing goes directly to the pressure switch port and is not tee'd into other devices incorrectly.
- Check for water in tubing: Remove the tube from the pressure switch and inducer. Blow through it to clear any condensate. Reinstall securely.
- Tap pressure switch: With power OFF, lightly tap the pressure switch body to free a stuck internal contact.
- Restart furnace: Restore power and call for heat. If the inducer still runs without progressing to ignition and E12 remains, the pressure switch may be stuck closed and should be replaced.
- Board check: If a new pressure switch does not resolve the issue, the control board input circuit may be faulty and require replacement.