E17
Kelvinator Limit or Rollout Lockout (Manual Reset Required)

Furnace displays E17 and runs the blower without heating; thermostat appears normal

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Repeated high limit trips, Manual-reset rollout switch open, Control board lockout after multiple safety trips

How to Fix / Troubleshooting

Safety first: Continuous safety trips indicate a serious problem. Turn OFF gas and power if you smell strong combustion odors or see scorch marks.

  • Check filter and airflow: Replace the furnace filter and ensure all registers are open to reduce overheating.
  • Inspect rollout switches: With power OFF, locate rollout switches near the burners. If they have a small reset button, press gently once. If they immediately trip again on the next cycle, shut the furnace down and call a technician.
  • Reset control board: Turn power OFF for 5 minutes, then restore. Some Kelvinator boards require cycling the thermostat from HEAT to OFF and back to clear lockout.
  • Professional inspection: If E17 returns, a technician must inspect the heat exchanger, venting, and burner operation before the furnace is used again.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Flame Rollout Switch
Check Price on Amazon

We may earn a commission from links on this page.