E18
Kelvinator Emergency Fan Mode / Limit Circuit Open

Kelvinator furnace shows E18 and the blower runs at high speed continuously

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open high limit switch, Broken wire in limit circuit, Faulty limit wiring harness, Control board reading open limit when cool

How to Fix / Troubleshooting

Safety first: Turn OFF power before checking limit wiring. Components may still be hot.

  • Locate high limit: Find the main high limit switch mounted on the heat exchanger panel. Check that its wires are firmly connected.
  • Inspect wiring harness: Follow the limit circuit wires from the switch back to the control board. Look for breaks, burns, or loose plugs.
  • Cool-down test: Allow the furnace to sit with power OFF for 30 minutes to cool. Restore power. If E18 appears immediately without a heat call, the limit switch may be stuck open and require replacement.
  • Replace limit switch: Use a Kelvinator-approved limit with the same temperature rating. Do not bypass the limit switch.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

High Limit Switch
Check Price on Amazon