Oversized furnace for home, Thermostat located near supply register, Dirty flame sensor causing intermittent flame loss, High limit cycling from restricted airflow

How to Fix / Troubleshooting

Safety first: Turn OFF power before accessing internal components.

  • Check filter and airflow: Replace the filter and ensure registers are open to prevent limit trips.
  • Clean flame sensor: Remove and gently clean the flame sensor rod with fine steel wool, then reinstall.
  • Thermostat location: Make sure the thermostat is not directly in the path of a supply register or in direct sunlight. Redirect airflow or relocate thermostat if necessary.
  • Professional evaluation: If short cycling persists, a technician should check furnace sizing, gas input, and Kelvinator control settings.