E09
Kospel DHW Temperature Sensor Fault

Furnace displays E09 and stops; may occur when domestic hot water is drawn (on combi models).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed DHW NTC sensor, Loose wiring to DHW sensor, Scale buildup affecting sensor pocket, Short circuit in sensor cable

How to Fix / Troubleshooting

Safety: Disconnect power and close water valves if removing any wet components.

  • Locate DHW sensor: On Kospel combi furnaces, the DHW NTC is usually mounted on the DHW heat exchanger or outlet pipe.
  • Inspect wiring: Check the cable and connector for damage or corrosion. Reseat the plug on the control board.
  • Check for scale: If accessible, inspect the sensor pocket for limescale buildup which can insulate the sensor. Descale according to Kospel guidelines.
  • Replace sensor if needed: If the sensor is physically damaged or tests out of range, install a new Kospel DHW NTC sensor.

Restore power and test DHW operation to ensure the error is cleared.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

DHW Temperature NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements